London LON-11 Data Center
Coriander Avenue, London, E14 2AA, United Kingdom
Facility LEED Certified Tier III Data Center
Security: Physical, Human & Electronic
Green power: Yes
Why LON-11?
Leaseweb's cutting edge LON-11 data center in London is designed for Data and Mission Critical operations boasting low-latency and lightning fast global connectivity to LINX and Lonap. Our new data center offers a wide variety of our most popular dedicated servers and an extensive range of cloud services, from enterprise class performance vCloud to Apache CloudStack and VMWare-based Private Cloud solutions – all with expert local support.
Location details

Facility
- 53,820 sq ft facility
- 6 x 2.7MW chillers N 2 configuration
- Room Air Conditioning Units (RACUs) to provide down-flow chilled water system at N 25%
- The systems are designed to minimize any possible customer disruption and ensure that any minor problems remain localized

Connectivity
Carriers:
- Telia
- TATA
- Cogent
- GTT
Internet Exchanges:
- LINX
- Lonap

Power
- Four redundant HV power systemsfrom separate grids to each building on the Docklands site
- Standard generators with a minimum of 24 hours autonomy at full capacity
- 8 x 2.5MVA 11kV Generators with N+1 redundant standby generators with a minimum of 24 hours autonomy at full capacity
- 2 (N+1) redundant UPS floor by floor
- Redundant A & B power feeds to customer equipment
- On-site primary substation with total capacity of 50MVA including cooling, and two 132kV power lines directly connected to the National Grid with two transformers providing N+N redundancy

Fire Suppression
- Data center areas are fitted with a fully addressable two stage fire detection system that monitors both under-floor and the room itself
- Detectors with 50% mix of optical and ionization are split across 2 separate zonal-loops, to meet BS 5839, 6266, 5445 and 5588
- Very early smoke detection alarms (VESDA) installed throughout the facility
- Dry sprinkler fire detection system to meet BS 5306, 3115 and with LFEPA approval. Dry sprinkler is the main fire suppression method employed

Security
- Perimeter protected by alarmed fences and PIR detection
- Gated entrances manned combined with a security management system to ensure no unauthorised access to the site
- Movement activated CCTV coverage for the Perimeter, Entrances and Loading Docks, Common areas reception and corridors and of course our state of the art suites
- Single point of entry to our main facilities controlled by time limited access cards combined with card Independent client card identification access system and integrated digital video camera surveillance
- Proximity card access is provided from the main data centre building and is issued to provide access only to authorised facilities management suites
- Strict security processes are in place to ensure delivery and loading of goods are secure
- Doors fitted with alarms that immediately report back to a manned security suite when unauthorised access is attempted or doors are forced or held open
- A highly trained Security presence 24/7 to ensure that you and your nominated staff gain authorised access to the facility whenever you require, day or night
- Independent client card identification access system
- Secure and monitored single-person point of entry, physically guarded 24/7 and integrated digital video camera surveillance

Certifications
- ISO 9001
- ISO/IEC 27001
- PCI – DSS
- BS 25999-2
- ISO 14001